  • 您現在的位置:首頁 > 新聞資訊 > 行業新聞 >
  • 無菌室裝修設計規范化要求是什么?
    來源:http://www.nexregen.com 瀏覽: 發布日期:2020-07-11
    無菌室也稱接種室,是系統接種、純化菌種等無菌操作的專用實驗室。在微生物工作中,菌種的接種移植是一項主要操作,這項操作的特點就是要保證菌種純種,防止雜菌的污染。在一般環境的空氣中,由于存在許多塵埃和雜菌,很易造成污染,對接種工作干擾很大。小析姐為您介紹下微生物無菌室裝修設計規范化。
    Aseptic room, also known as inoculation room, is a special laboratory for aseptic operation such as systematic inoculation and purification of bacteria. In the microbial work, the inoculation and transplantation of bacteria is a major operation. The characteristics of this operation are to ensure the purity of strains and prevent the contamination of miscellaneous bacteria. In the air of general environment, because of the existence of many dust and miscellaneous bacteria, it is easy to cause pollution, which greatly interferes with the vaccination work. Xiaojie introduces the standardization of decoration design of microbial aseptic room for you.
    無菌室應根據既經濟又科學的原則來設置。其基本要求有以下幾點:
    Aseptic room should be set up according to the principle of economy and science. The basic requirements are as follows:
    (1)無菌室應有內、外兩間,內間是無菌室,外間是緩沖室。房間容積不宜過大,以便于空氣滅菌。內間面積2×2.5=5m2,外間面積1×2=2m2,高以2.5m以下為宜,都應有天花板。
    (1) The aseptic room should have internal and external rooms. The inner room is the sterile room and the outer room is the buffer room. Room volume should not be too large to facilitate air sterilization. The inner area is 2 × 2.5 = 5m2, and the outer area is 1 × 2 = 2M2. The height should be less than 2.5m, and there should be ceiling.
    (2)內間應當設拉門,以減少空氣的波動,門應設在離工作臺更遠的位置上;外間的門更好也用拉門,要設在距內間更遠的位置上。
    (2) Sliding door should be set in the inner room to reduce the air fluctuation. The door should be set at the farthest position from the working table; the door of the outer room should also use the sliding door, which should be set at the farthest position from the inner room.

    (3)在分隔內間與外間的墻壁或“隔扇”上,應開一個小窗,作接種過程中必要的內外傳遞物品的通道,以減少人員進出內間的次數,降低污染程度。小窗寬60cm、高40cm、厚30cm,內外都掛對拉的窗扇。
    (3) A small window should be opened on the wall or "partition" separating the internal and external rooms, which is necessary for the internal and external transmission of articles during the inoculation process, so as to reduce the number of people entering and leaving the inner room and reduce the pollution degree. The window is 60cm in width, 40cm in height and 30cm in thickness.
    (4)無菌室容積小而嚴密,使用一段時間后,室內溫度很高,故應設置通氣窗。通氣窗應設在內室進門處的頂棚上(即離工作臺更遠的位置),更好為雙層結構,外層為百葉窗,內層可用抽板式窗扇。通氣窗可在內室使用后、滅菌前開啟,以流通空氣。有條件可安裝恒溫恒濕機。
    (4) The volume of aseptic room is small and tight. After using for a period of time, the indoor temperature is very high, so ventilation window should be set. The ventilation window should be set on the ceiling at the entrance of the inner room (i.e. the farthest position from the working table). It is better to have a double-layer structure. The outer layer is made of louvers, and the inner layer can be made of draw plate window fans. The ventilation window can be opened after the inner chamber is used and before sterilization to circulate air. If possible, constant temperature and humidity machine can be installed.